USE OF TRANEXAMIC ACID DURING KNEE JOINT ENDOPROSTHETIC REPLACEMENT
Issue:
7
Year:
2015
The use of tranexamic acid during knee joint endoprosthetic replacement should be considered as an adequate procedure to reduce blood loss and patient needs for donor blood transfusions.
Keywords:
knee joint endoprosthetic replacement
blood loss
cardiac risk
tranexamic acid
blood saving
References:
- Borisov D.B., Kirov M.Ju. Primenenie traneksamovoj kisloty pri endoprotezirovanie krupnyh sustavov // Novosti hirurgii. – 2013; 21 (4): 107–13.
- Tihilov R.M., Serebrjakov A.B, Shubnjakov I.I. i dr. Vlijanie razlichnyh faktorov na krovopoterju pri endoprotezirovanii tazobedrennogo sustava // Travmatol. i ortopedija. – 2012; 3 (65): 5–11.
- Kavalerskij G.M., Murylev V.Ju., Elizarov P.M. i dr. Total'noe endoprotezirovanie kolennogo sustava s ispol'zovaniem komp'juternoj navigatsii pri tjazhelyh deformatsijah konechnostej // Vestn. travmatol. i ortopedii im. N.N. Priorova. – 2010; 2: 34–40.
- Murylev V.Ju., Holodaev M.Ju., Elizarov P.M. i dr. Endoprotezirovanie kolennogo sustava pri ego massivnyh destruktsijah u ortopedicheskih bol'nyh // Vrach. – 2012; 2: 74–81.
- Shevchenko Ju.L, Stojko Ju.M., Zamjatin M.N. Krovosberegajuschij effekt traneksamovoj kisloty pri protezirovanii kolennogo sustava // Obschaja reanimatol. – 2008; 4 (6): 1–4.
- Tihilov P.M. i dr. Primenenie preparata traneksam pri pervichnom i revizionnom endoprotezirovanii tazobedrennogo sustava. Meditsinskaja tehnologija / FGU «RNIITO im. R.R. Vredena, 2010; s. 19.
- Zhi-Gao Yang, Wei-Ping Chen, Li-Dong Wu. Effectiveness and Safety of Tranexamic Acid in Reducing Blood Loss in Total Knee Arthroplasty: A Meta-Analysis // J. Bone Joint Surg. Am. – 2012; 94 (13): 1153–9.
- X. Aguilera, Martinez-Zapata M. Bosch A. et al. Efficacy and Safety of Fibrin Glue and Tranexamic Acid to Prevent Postoperative Blood Loss in Total Knee Arthroplasty: A Randomized Controlled Clinical Trial // J. Bone Joint Surg. Am. – 2013; 95 (22): 2001–7. doi: 10.2106/JBJS.L.01182
- Wong J., Abrishami A., El-Beheiry H., et al. Topical Application of Tranexamic Acid Reduces Postoperative Blood Loss in Total Knee Arthroplasty: A Randomized, Controlled Trial // J. Bone Joint Surg. Am. – 2010; 92 (15): 2503–13.
- Alshryda S., Mason J., Vaghela M. et al. Topical (Intra-Articular) Tranexamic Acid Reduces Blood Loss and Transfusion Rates Following Total Knee Replacement // J. Bone Joint Surg. Am. – 2013; 95 (21): 1961–8.
- Levy O., Martinowitz U., Oran A. et al. The Use of Fibrin Tissue Adhesive to Reduce Blood Loss and the Need for Blood Transfusion After Total Knee Arthroplasty. A Prospective, Randomized, Multicenter Study // J. Bone Joint Surg. Am. – 1999; 81 (11): 1580–8