REVISION HIP ARTHROPLASTY IN PATIENTS WITH PELVIC DISSOCIATION
Issue:
12
Year:
2017
The paper considers the classification, diagnosis, and treatment of pelvic dissociation, a severe complication of disruption of the anterior and posterior columns of the acetabulum. It shows various approaches and the state of the art of 3D technologies in acetabular surgery.
Keywords:
surgery
pelvic dissociation
acetabular defects
revision hip arthroplasty
computed tomography
3D printing
trabecular metal
References:
- Tihilov R.M., Shubnjakov I.I., Kovalenko A.N. i dr. Dannye registra endoprotezirovanija tazobedrennogo sustava RNIITO im. R.R. Vredena za 2007–2012 gody // Travmatol. i ortoped. Rossii. – 2013; 10 (3): 167–90.
- Berry D., Lewallen D., Hanssen A. et al. Pelvic discontinuity in revision total hip arthroplasty // J. Bone Joint Surg. Am. – 1999; 81: 1692–702.
- Kosashvili Y., Backstein D., Safir O. et al. Acetabular revision using an anti-protrusion (ilio-ischial) cage and trabecular metal acetabular component for severe acetabular bone loss associated with pelvic discontinuity // J. Bone Joint Surg. Br. – 2009; 91: 870–6.
- Taunton M., Fehring T., Edwards P. et al. Pelvic Discontinuity Treated With Custom Triflange Component. A Reliable Option // Clin. Orthop. Relat. Res. –2012; 470: 428–34.
- Berry D. Identification and management of pelvic discontinuity // Orthopedics. – 2001; 24 (9): 881–2.
- Abdel M., Trousdale R., Berry D. Pelvic Discontinuity Associated With Total Hip Arthroplasty: Evaluation and Management // J. Am. Acad. Orthop. Surg. – 2017; 25: 330–8.
- Martin J., Barrett I., Sierra R. et al. Preoperative radiographic evaluation of patients with pelvic discontinuity // J. Arthroplasty. – 2016; 31 (5): 1053–56.
- Kavalerskij G.M., Murylev V. Ju., Rukin Ja.A. i dr. 3D-tehnologii pri revizionnom endoprotezirovanii tazobedrennogo sustava // Vrach. – 2016; 11: 47–9.
- Kavalerskij G.M., Murylev V.Ju., Rukin Ja.A. i dr. Primenenie individual'nyh vertluzhnyh komponentov pri revizionnom endoprotezirovanii tazobedrennogo sustava // Travmatol. i ortoped. Rossii. – 2016; 4 (22): 114–21.
- Tihilov R.M., Shubnjakov I.I., Kovalenko A.N. i dr. Primenenie individual'noj trehflantsevoj konstruktsii pri revizionnom endoprotezirovanii tazobedrennogo sustava s narusheniem tselostnosti tazovogo kol'tsa. Klinicheskij sluchaj // Travmatol. i ortoped. Rossii. – 2016; 1 (79): 108–16.
- Rogers B., Whittingham-Jones P., Mitchell P. et al. The reconstruction of periprosthetic pelvic discontinuity // J. Arthroplasty. – 2012; 27 (8): 1499–506.
- Bobyn J., Hacking S., Chan S. et al. Characterization of new porous tantalum biomaterial for reconstructive orthopaedics. Scientific Exhibition: 66th Annual Meeting of the American Academy of Orthopaedic Surgeons, 1999; Anaheim, CA.
- Sporer S., Bottros J., Hulst J. et al. Acetabulardistraction: An alternative for severe defectswith chronic pelvic discontinuity? // Clin. Orthop. Relat. Res. – 2012; 470 (11): 3156–63.
- Kosashvili Y., Backstein D., Safir O. et al. Acetabular revision using an anti-protrusion (ilio-ischial) cage and trabecular metal acetabular component for severe acetabular bone loss associated with pelvic discontinuity // J. Bone Joint Surg. Br. – 2009; 91 (7): 870–6.
- Amenabar T., Rahman W., Hetaimish B. et al. Promising mid-term results with a cup-cageconstruct for large acetabular defects andpelvic discontinuity // Clin. Orthop. Relat. Res. – 2016; 474 (2): 408–14.
- Berasi C., Berend K., Adams J. et al. Are custom triflange acetabular components effective for reconstruction of catastrophic bone loss? // Clin. Orthop. Relat. Res. – 2015; 473 (2): 528–35.
- DeBoer D., Christie M., Brinson M. et al. Revision total hiparthroplasty for pelvic discontinuity // J. Bone Joint Surg. Am. – 2007; 89 (4): 835–40.